CCommons

Why does a potentiometer measure emf better than a voltmeter, and what actually increases its sensitivity?

A question about balance points, driver cells and a gradient I cannot picture.

Zoya Khan12th Sample

1 Sept 2026 · 1 min read

I like understanding the "why" behind instruments, but the potentiometer section is not giving me a clear picture. I will write what I understand and where it breaks.

A long uniform wire of length LL is connected to a driver cell. The potential gradient is k=V/Lk = V/L (potential drop per unit length). A cell of emf EE is connected through a galvanometer to a sliding jockey, and at the balance point at length ll the galvanometer shows zero deflection, so E=klE = kl. To compare two cells, E1/E2=l1/l2E_1/E_2 = l_1/l_2.

Where I'm stuck:

  1. NCERT says the potentiometer measures emf "without drawing any current from the cell". But the jockey is connected through the cell to the wire... so how is the current really zero? And why is a voltmeter worse?
  2. Why must the driver cell's emf be greater than the emf of the cell I want to measure? What happens if it is smaller?
  3. For internal resistance, I remember r=R (l1−l2)l2r = R\,\dfrac{(l_1 - l_2)}{l_2}. What do l1l_1 and l2l_2 stand for? I keep forgetting which one is with the key closed.
  4. How do I make the potentiometer more sensitive?
WhatsAppPost on X

7 answers & replies

Sign in to join the conversation.

  • [+]Arjun Nair12thSample· 1mo ago
    1. At the balance point, the potential difference across the length ll of the wire exactly equals the emf of the cell, so the two push equally against each other and the galvanometer carries zero current. That means the cell neither delivers nor takes current, so we are measuring its actual emf. A voltmeter always has finite resistance, draws a small current, and the terminal voltage it reads is E−IrE - Ir, a little less than the emf.

    2. Along the wire, the potential drops from the driver's full value to near zero. For the balance point to exist somewhere along the wire the drop across the whole wire must be at least EE. If the driver emf is smaller there is no point where the drop equals EE and the galvanometer never reads zero.

  • [+]Rahul DubeyDropperSample· 1mo ago
    1. Internal resistance: l1l_1 is the balance length with the key open (cell on no load, so you are measuring emf). l2l_2 is the balance length with the key closed (cell sends current through the known resistance RR, so you are measuring terminal voltage VV). Since E=kl1E = kl_1 and V=kl2V = kl_2, and V=E−IrV = E - Ir with I=V/RI = V/R, you get r=R(l1−l2l2)r = R\left(\dfrac{l_1 - l_2}{l_2}\right).

    Memory hook: l1l_1 comes first and is bigger (open circuit gives the larger voltage), l2l_2 is the smaller one.

    • [+]Zoya Khan12thSample· 1mo agoAuthor

      The "l₁ is bigger" hook helped. I couldn't remember the order before. Thank you for the patient answers everyone.

  • [+]Harsh Gupta12thSample· 1mo ago

    Sensitivity: increase the current in the main circuit by reducing the rheostat resistance, so the wire has a bigger voltage drop and the balance point is clearer.

    • [+]Kavya NaikDropperSample· 1mo ago

      Harsh, I think that's the opposite! Sensitivity improves when the potential gradient kk is smaller, because a small change in jockey position then corresponds to a very small change in potential and you can balance more precisely. So reduce the current in the main circuit (add resistance via the rheostat), or use a longer wire. The trade-off is that the driver's drop across the wire must still be larger than the emf you want to measure.

      • [+]Harsh Gupta12thSample· 1mo ago

        Oops. I got it backwards, I was thinking "more current more signal". Kavya didi is right: smaller gradient, finer reading. Moving to a career in standup where nobody checks the physics.

  • [+]Vivek Mishra12thSample· 1mo ago

    Exam note. Two advantages that come up in statement questions: it is a null method, so no current is drawn from the cell being measured, and its sensitivity can be raised by lowering the potential gradient (longer wire). The main disadvantage is that it needs a long wire and a steady driver cell, so it is not handy for quick readings.